GB
WIKA operating instructions DELTA-plus, DELTA-comb and DELTA-switch12
14093265.01 03/2014 GB/D/F/E
14077608.01
⊖ ⊕
DELTA-switch model DPS40
Pressures p
1
and p
2
act on the media chambers ⊕ and ⊖, which are separated
by an elastic diaphragm (1).
The dierential pressure (∆p = p
1
- p
2
) leads to an axial deection of the
diaphragm against the measuring range springs (2).
The deection, which is proportional to the dierential pressure, is transmitted to
the leaf springs of the micro switches (4) in the switch case via a pressure-tight
and low-friction rocker arm (3).
Overpressure safety is provided by metal bolsters (5) resting against the elastic
diaphragm.
The adjustment of the switch point is made by the adjustment screws accessi-
ble from the front (6). The assistant scales (7) enable an accurate setting of the
switch points and indicate the current set point.
4.2 Scope of delivery
Cross-check scope of delivery with delivery note.
4. Design and function