11286700 D/GB/F/E 07/2007
GB
6. Technical data
Versions
TR70-A: Pt100 with two switching outputs
TR70-B: Pt100 with one switching output and one analogue output
Temperature ranges
-50 to +200 °C
-50 to +400 °C
-50 to +600 °C
-200 to +600 °C
Measurement units
°C or F (selectable)
Sensor
Pt100 class B or Pt100 class A
Supply voltage
12...30V DC, overload and reverse polarity protection ripple <10 %
Power consumption
≤ 50 mA, without load current
Process connections
• Fixed thread
• Compression fitting
G1/2 A, G1/4 A, G3/8 A, G3/4 A, 1/2NPT, 1/4NPT
G1/2 A, G3/8 A, G1/4 A, 1/2NPT
Other connections on request
Werkstoffe
• Process connection
• Housing
Stainl
ess steel 1.4571 (316Ti); other materials or coatings on request
Stainless steel, display cover plastic
Stem and
working pressure
• from stem length (EL) 50 mm: ø6 x 0.75 mm (up to 40 bar)
• from EL 50 mm: ø8 x 1.75 mm (up to 100 bar)
• from EL
50mm: Special parts made of solid material (up to 500 bar)
Fast response time version (up to 12bar)
• EL 25 mm: ø3 x 0.25 mm without taper
• EL up to 100 mm: ø6 x 0.25 mm with taper to ø3 x 0.25 mm
• fro
m EL 100mm: ø8 x 1.75mm with taper to ø6 x 0.25mm with taper
to ø3 x 0.25 mm
Outputs
2 switching outputs PNP or
1 switching output PNP and analogue output 4 … 20mA
Betriebsanleitung / Operating manual / Instructions de service / Instrucciones de uso TR7030