Seitenansicht 5
INSTRUCTION MANUAL
NI-492E
Rev. 0 01/05
ETTORE CELLA SPA Viale de Gasperi, 48 - Casella Postale (P.O. Box) 58 - I 20010 Bareggio (MILANO) ITALY
Telefoni +39 029036.1146/1237/1241 - FAX +39 029036.1331 E-MAIL: [email protected]
Fig. 8 - Examples of mounting Fig. 9 - Mounting with junction box
1) Temperature switch Series TX 5) Coupling 9) Sleeve 13) Blocking joint
2) Capillary tubing 6) Process line 10) Three-piece joint 14) Junction box
3) Thermowell 7) Mounting bracket 11) Box
4) Bulb 8) 2” pipe / Surface 12) Extension
Fig. 10 - Mounting with cable loose Fig. 11 - Thermowells: examples of installation
Mounting on elbow - Minimum pipe size is to be 3", if less,
provide a pipe enlargement up to 3".
Mounting on straight pipe – Minimum pipe size 3”, if less
provide a pipe enlargement up to 6".
Fig. 12 - Mounting directly on box