Wika 54_twintemp Bedienungsanleitung Seite 8

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 60
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 7
GB
14004105.01 05/2011 GB/D/F/E
8 WIKA operating instructions model 54, Twin-Temp
3. Specications
Specications
Model 54, Twin-Temp
Measuring element Bimetal helix and Pt100
Nominal size 63, 80, 100, 160
Instrument version
Model A5x
Model R5x
Rear mount (axial)
Lower mount (radial)
Permissible ambient
temperature
at the housing max. +60 °C (other versions
on request)
Working pressure
Continuous load (1 year)
short term (max. 24 h)
Measuring range (DIN EN 13190)
Scale range (DIN EN 13190)
Case, ring
Stainless steel 1.4301
Stem, process connection
Stainless steel 1.4571
Ingress protection
IP 65 per EN 60529 / IEC 529
IP 66, liquid-lled
For further specications see WIKA data sheet TV 15.01 and the
order documentation.
4. Design and function
4.1 Description
This series of thermometers is designed for installation in pipes,
vessels, plant and machinery.
The „Twin-Temp“ combined bimetal thermometer oers two
measuring systems in one instrument.
A bimetal thermometer enables the visualisation of measured values
on site without power supply, while, in addition, the integrated Pt100
resistance sensor provides an electrical signal for further processing.
This design is particularly recommended for safety-critical applica-
tions and in case of limited space where the process can be opened
only at one place.
3. Specications / 4. Design and function
Seitenansicht 7
1 2 3 4 5 6 7 8 9 10 11 12 13 ... 59 60

Kommentare zu diesen Handbüchern

Keine Kommentare