151
13.2 Model Key
1) inclusive PACTware Starter Version for configuration
2) only with accuracy 0.5%; max. Turndown 2:1
3) max. temperature of medium 60°C
4) only in conjuction with aluminum case; not in conjuncction with electrical connection code M (M12x1 plug)
Signal output
A 4 ... 20 mA, 2-wire
1R
4 ... 20 mA with HART
®
protocol, 2-wire
1)
Unit
B bar
2Sbar absolut bis 16 bar abs
Pressure range
CA -1 bar ... 0 bar BM 0 bar ... 40 bar
CD -1 bar ... 0,6 bar BO 0 bar ... 100 bar
CH -1 bar ... 3 bar BQ 0 bar ... 250 bar
CK -1 bar ... 5 bar BT 0 bar ... 600 bar
CP -1 bar ... 15 bar BU 0 bar ... 1000 bar
BB 0 bar ... 0.4 bar / bar absolute BV
0 bar ... 1600 bar
2
only with aluminium case
BE 0 bar ... 1.6 bar / bar absolute BX
0 bar ... 2500 bar
2
only with aluminium case
BH 0 bar ... 6 bar / bar absolute BZ
0 bar ... 4000 bar
2
only with aluminium case
3BK0 bar ... 16 bar / bar absolute
Process connection
GD G ½ B ML
M16 x 1.5 female, with sealing cone from 1600 bar
ND ½ NPT MP M20 x 1.5 female, with sealing cone from 1600 bar
VZ 9/16 - 18 UNF female F 250-C from 1600 bar
4CSchemical seal prices and designs according to chemical seals product range
Special design features
Z without
E oil and grease free
A
oxygen, oil and grease free
3)
up to 1000 bar abs
5O
overvoltage protection according to IEC 801-5
Case material
M highly resistive, fiberglass-enforced plastic (PBT)
6AAluminium Ingress protection IP 67
Temperature range of medium
T -30 ... +105 °C (-22 ... +221 °F)
7E-20 ... +60 °C (-4 ... +140 °F) only for oxygen version
Electrical connection
A cable gland M20x1.5 with internal terminal block standard
8M
4 pin locking plug M12x1
Digital display
Z without
9A
with integrated 4-digit LCD-display
Approvals
L EEx ia IIC T4-T6 in compliance with ATEX 100a II 1/2 G for connection to zone 0
X
EEx IP6X 1/2D, 2D + EEx ia IIC T4-T6 1/2G, 2G per ATEX
4)
10 C
CSA
Additional order info
YES NO
11 1 Z quality certificates
12 T Z additional text
Order code: