Wika TR25 Bedienungsanleitung Seite 10

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 52
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 9
14073045.01 10/2013 GB/D
10
WIKA operating instructions model TR25 (Ex i)
GB
Pressure equipment directive
For instruments with nominal widths of ≤ DN 25 (1“), an EC conformity evaluation in
accordance with the Pressure Equipment Directive (PED) is not permitted.
Instruments with nominal widths of ≤ DN 25 (1“), and thus without CE marking, should be
designed and manufactured in line with the applicable sound engineering practice (PED
article 3, chapter 3).
For instruments > DN 25 (1“) and for the associated marking on the measuring instrument
or thermowell, WIKA conrms conformity with the 97/23/EC Pressure Equipment Directive in
accordance with the conformity assessment procedure, module H.
For further specications see WIKA data sheet TE 60.25 and the order documentation.
4. Design and function
4.1 Description
This resistance thermometer, through a wide variety of process connections, enables trouble-free
connection to many dierent processes.
3- or 4-wire platinum measurement resistances in accuracy classes A and B per DIN EN 60751
serve as sensors.
Analogue or digital transmitters built into the connection head are capable of making various
output signals available, for example 4 ... 20 mA, HART
®
protocol, FOUNDATION™ eldbus or
PROFIBUS
®
PA.
3. Specications / 4. Design and function