WIKA operating instructions temperature transmitter, model T24 13
2370242.09 08/2013 GB/D
5.3 Storage
Permissible conditions at the place of storage:
Storage temperature: -40 ... +85 °C
Humidity: 95 % relative humidity (condensation allowed)
Avoidance of exposure to the following factors:
Direct sunlight or proximity to hot objects
Mechanical vibration, mechanical shock (putting it down hard)
Soot, vapour, dust and corrosive gases
Potentially explosive environments, ammable atmospheres
Store the instrument in its original packaging in a location that fulls
the conditions listed above. If the original packaging is not available,
pack and store the instrument as described below:
1. Wrap the instrument in an antistatic plastic lm.
2. Place the instrument, along with shock-absorbent material, in the
packaging.
3. If stored for a prolonged period of time (more than 30 days), place a
bag containing a desiccant inside the packaging.
WARNING!
Before storing the instrument (following operation),
remove any residual media. This is of particular impor-
tance if the medium is hazardous to health, e.g. caustic,
toxic, carcinogenic, radioactive, etc.
5. Transport, packaging and storage