8. Safety-related instructions for the dierent variants
11419904.02 09/2013 GB/D
WIKA operating instructions models TR12, TC12 (Ex d)22
A heating in the connection head does not occur with variant 1. However, an impermissible
heat reux from the process which can exceed the operating temperature of the housing or
the temperature class, must be prevented through suitable heat insulation or a suitably long
neck tube.
8.2 Variant 2:
ATEX/IECEX Ex d housing or connection head with built-in head-mounted transmitter.
The evaluation is made via a current (4 … 20 mA), voltage (2 … 10 V) or eld bus signal,
which is generated from a head-mounted transmitter.
Use in zone 1, marking II 2G Ex d IIC T1-T6 Gb
The ameproof housing or the connection head is in zone 1 (or zone 2). The sensor is in
zone 1. In the case of a separation of Ex-zones, a thermowell (from corrosion-resistant
steel, min. wall thickness 1 mm) must be used.
Use with a thermowell at the partition to zone 0, marking II 1/2G Ex d IIC T1-T6 Ga/Gb
The ameproof housing or the connection head is in zone 1 (or zone 2). The sensor is
within a thermowell (min. wall thickness 1 mm) which extends into zone 0 via a process
connection.
The thermometer should be operated with a power-limiting circuit.
P
max
: 2 W
U
max:
30 V
A power supply with Ex ia circuitry fullls these conditions, but is not required if the limits
can be achieved through other measures. The responsibility rests with the operator.
WIKA recommends realising the power limitation through a suitable fuse in the 4 ... 20 mA
current loop of the head-mounted transmitter. In the event of a failure, the head-mounted
transmitter will circuit will be interrupted through the fuse tripping.
Example for calculating the fuse for a maximum power at the sensor of 0.8 Watt:
The internal resistance of thermocouples is signicantly lower than the thermal resistance
of a Pt100 sensor, so the much less favourable case for a resistance thermometer has been
calculated.
P
max
= (1.7 x I
s
)² x Rw
I
s
= Fuse rating
P
max
= maximum power at sensor = 0.8 W
R
w
= Resistance of the sensors (temperature dependant)
at 450 °C = 264.18 Ω in accordance with DIN EN 60751 for Pt100.
The following denes the fuse rating:
I
s
= sqrt (P
max
/ R
w
) / 1.7
I
s
= sqrt (0.8 W / 265 Ω) / 1.7
I
s
= 32.32 mA
This results in a rated current for a fuse link = 32 mA