3.1 Transmitter
1)
Power supply U
B
DC V
12 U
B
30≤
Supply voltage effect
% of FS/10 V
0.1
Permissible residual ripple
% ss
10
Output signal, variant I 4 … 20 mA, 2-wire, passive, per NAMUR NE43
Permissible max. load R
A
R
A
(U
B
- 12 V)/0.02 A with R
A
in Ohm and U
B
in Volt
however max. 600
Effect of load
% FS
0.1
Output signal, variant II 4 … 20 mA, 2-wire - Ex≤, per ATEX Ex II 2G Ex ia IIC T4/T5/
T6 or Ex I M2 Ex ia I
Output signal, variant III 0 ... 20 mA, 3-wire
2)
Output signal, variant IV 0 ... 10 V *
Impendance on the voltage output
0.5
Load-carrying ability voltage output
k
2 … 100
Sample rate sensor
ms
600, with 3-wire optionally faster
Electrical zero point
Zeroing through short-term jumper across ternimals 5 and 6
Zero point adustable range
< °
45
Linearity
% of span
1.0 (limit point calibration)
Output signal accuracy
% FS
0.2 (only electronic)
Resolution
% FS
0.15 (10 bit resolution at 360°)
Update rate (measuring rate)
1/s
> 1
Input signal rotational angle
< °
0 … 270
Expanded special span
< °
< 330 (Option)
Long-term stability of electronics
% FS/a
< 0.3
Temperature error, electronics
% FS/10K
< 0.3 (over the complete temperature range)
Warming-up time
min.
5
Permissible ambient temperature
°C
-40 … +60
Permissible storage temperature
°C
-40 … +70
Permissible medium temperature
°C
-40 … +100
Special function Option: non-proportional angular output signal, via auxili-
ary points and interpolation of the intermediate values (to
specify with the order)
CE-conformity Interference emission and immunity per EN 61 326-1
Wiring L-plug connector, 180 °C rotatable, max. 1.5 mm², wire
protector, Cable gland M20 x 1.5, External cable diameter
7-13 mm, incl. strain relief
Wiring protection IP65 to EN 60 529 / IEC 529;
Protected against reverse polarity and overvoltage
Connection details,
depending on variant
Terminal
No
1
2
3
4
5
6
Variant I
4 ... 20mA
GND
I+
reserved
reserved
Zeroing
Zeroing
Ex-Variant II
4 ... 20mA
GND
I+
reserved
reserved
Zeroing
Zeroing
Variant III
0 ... 20 mA
GND
U
B
+
I
out
reserved
Zeroing
Zeroing
Variant IV
0 ... 10V
GND
U
B
+
U
out
reserved
Zeroing
Zeroing
1) Not model PGT23.063
2) Not model DPGT43HP.100 / DPGT43HP.160
)
)
3. Technical data
)