GB
3. Technical data
3.10 Model DPGT43HP.100 / DPGT43HP.160
Working pressure
- Steady Full scale range
- Fluctuating 0.9 x full scale range
- Overload capability 40, 100, 250 or 400 bar
Temperature influence
max. ± 0.5 % of full scale range/10 K (when the temperature of the
measuring system deviates from +20 °C reference temperature)
IP protection class
- Housing IP 54 per EN 60 529 / IEC 60 529
- With liquid filling IP 65
Permissible temperatures
- Ambient filled/unfilled -20 ... +60 °C
- Medium maximum +100 °C
Further technical data see data sheet PV 17.13
11297264 05/2009 GB/D/F/E