3. Specications
Specications CPT62I0 reference pressure sensor
Pressure connection
1)
G½ B; {ush diaphragm (G1 for 0.1 up to 1.6 bar) or various connection adapters
on request}
Material
Wetted parts Stainless steel or Elgiloy
®
, (> 25 bar with NBR seal)
ush diaphragm version: stainless steel {Hastelloy C4}; O-Ring: NBR
3)
{FKM/FPM
or EPDM}
Internal transmission uid Synthetic oil, (only for pressure ranges up to 16 bar or ush diaphragm)
{Halocarbon oil for oxygen applications}; {Listed by FDA for food industry}
One year stability 0.2 % of span at reference conditions
Permissible
Medium temperature
1)
°C -20 ... +50 (T4)
Ambient temperature °C -20 ... +50 (T4)
Storage temperature °C -40 ... +80
Protection class IP 67 (Sensor) / IP 54 (Plug)
Compensated range °C 0 ... 70
Temperature coecients
Mean TC of zero signal 0.2 % / 10 K (< 0.4 for pressure ranges < 250 mbar)
Mean TC of span 0.2 % / 10 K
Supply circiut
Max. voltage DC V U
i
= 10,4
Max. strength of current mA I
i
= 93
Max. power mW P
i
= 500
Max. eective internal capacitance nF C
i
= 600
Max. eective internal inductance L
i
negligible
CE conformity
Pressure equipment directive 97/23/EC
EMC directive 2004/108/EC, EN 61326 Emission (Group 1, Class B) and Immunity (portable
equipment)
ATEX directive 94/9/EC, Category 2G, Ignition protection type Ex ib IIC T4
Connection to CPH62I0 via 1 m cable (plug & play); on request: up to 5 m
Weight g approx. 220
1) In an oxygen version, a ush diaphragm model is not available. In an oxygen version model CPT62I0 is only available in gauge pressure ranges ≥ 0.25
bar with media temperatures between -10 … +50 °C and using stainless steel or Elgiloy
®
wetted parts.
2) For the intrinsically safe version, the use of the interface and analogue output is not permitted within an explosive atmosphere.
3) O-ring made of FKM/FPM or EPDM for ush diaphragm with integrated cooling element.
{} Items in curved brackets are optional extras for additional price.
For further specications see WIKA data sheet
CT 11.02
and the order documentation.
WARNING!
For further important safety instructions for the operation in hazardous
areas see chapter “2.3 Additional safety instructions for instruments
with ATEX approval”.