D-20-9 / D-21-9 GB
WIKA Additional Instructions Pressure Transmitter with CANopen Interface D-20-9 / D-21-9 32
6132h AI Decimal Digits
Object description
This object describes the number of decimal digits following the decimal point.
Entry description
Sub-Index 00h
Name number of entries
Access ro
PDO Mapping No
Data Type UNSIGNED 8
Default Value 01h
Sub-Index 01h
Name AI Decimal Digits 1
Access rw
PDO Mapping No
Data Type UNSIGNED 8
Default Value 00h
Data Range 0 - 9
The settings take effect after a reset.
Changed parameters are not automatically stored, but they have to be stored via object 1010h Store
Parameters.
Furthermore the device can be reset to the factory settings via object 1011h Restore Default Parameters.
6148h AI Span Start
Object description
This value specifies the lower limit where process values are expected.
Entry description
Sub-Index 00h
Name number of entries
Access ro
PDO Mapping No
Data Type UNSIGNED 8
Default Value 01h
Sub-Index 01h
Name AI Span Start 1
Access ro
PDO Mapping Yes
Data Type float
Default Value No